THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD

A3 — close the pilot reliability gap

DocumentBMT-A3-ONE-PAGE-D1
Revision / review dateD1 · 2027-06-30
Accountable ownerAlex Meadow

Scope: A3 — close the pilot reliability gap. Read the observations and decisions below within their stated conditions.

Understand the gap

BackgroundCurrent conditionTargetRoot cause
BMT controlled pilot needs repeatable containment and indicationBasic 12/100 rebounds; Hotel 8/100 missed alerts; Drone 3/100 command faults0 failures in 1000 confirmation trials per critical functionBasic hinge stack; Hotel non-retained occupancy; Drone permissive reset path

Countermeasures and plan

ProductCountermeasureOwner / completionFollow-up / decision
BasicKey hinge, positive latch; functional gaugeSam Reed / 2027-05-200/1000 cycles and 10/10 retention pulls; pilot accepted
Mouse HotelRetain occupancy until local reset; radio-independent indicationJordan Vale / 2027-05-220/1000 missed local alerts; supervised bench accepted
Drone TrapHardware inhibit plus reset-state interlockJordan Vale / 2027-05-240/1000 unsafe enables; 30/30 loss injections inhibited; flight denied

Check and sustain

ReviewResultStandardization
Ira Bell 2027-06-18; Alex Meadow 2027-06-25Pilot targets met; 2027-06-30 follow-up 200 events each had 0 recurrenceD1 drawings, state machine, control plan and work instructions released internally; no public release.

Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.

Compare the reference example. Teaching data and signed dispositions: D1 scenario register.