THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD
Bow-tie — loss of containment or commanded release
Scope: Bow-tie — loss of containment or commanded release. Read the observations and decisions below within their stated conditions.
Hazard: stored movement / captive enclosure · top event: control of containment lost
| Threat → preventive barrier | Top event | Recovery barrier → consequence | Owner / proof |
|---|---|---|---|
| Hotel dropout → retained local occupied state | Containment / occupancy control lost | Human check and manual access → reduce unattended confinement | Jordan / 0 missed alerts in 1000 events |
| Hotel supply loss → battery-independent manual access | Containment / occupancy control lost | Local inspection routine → prevent prolonged unobserved occupancy | Robin / 10/10 manual accesses |
| Drone reset → normally inhibited output | Release control lost | Motor isolation and exclusion zone → prevent powered motion / exposure | Jordan / 0 unsafe enables in 1000 commands |
| Drone link loss → hardware inhibit | Release control lost | Bench stop and physical isolation → no flight or live payload | Ira / 30/30 injected losses inhibited |
Barrier degradation factors
| Factor | Control / verification | Review |
|---|---|---|
| Stale firmware or bypassed inhibit | D1 checksum and isolation witness before every trial; 3/3 bench setups matched | Alex signed June 25; all flight requests denied |
| Barrier independence | Local indication and hardware inhibit do not depend on radio command; tested by disconnected link | Ira verified June 18 |
Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.
Compare the reference example. Teaching data and signed dispositions: D1 scenario register.