THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD
Stop and fail-safe verification sheet
Scope: Stop and fail-safe verification sheet. Read the observations and decisions below within their stated conditions.
Surrogate rigs · June 18
| Product / energy | Stop demand | Safe state / reset | Measured trial | Disposition |
|---|---|---|---|---|
| Basic / spring and hand force | Stop cycle and isolate rig supply | Door remains mechanically retained; deliberate manual reset | 10/10 rig stops; retention 5 N 10/10 | Sam: pilot accepted |
| Hotel / low-voltage supply | Supply removal or operator stop | No powered movement; manual access retained; occupied indication checked locally | 10/10 power-loss manual recoveries; restart 10/10 requires reset | Jordan: supervised bench accepted |
| Drone / isolated actuator, motors disconnected | Link loss or bench stop | Release inhibit de-energized; no auto restart | 30/30 link losses inhibit; 10/10 stop/reset sequences safe | Ira: bench accepted; no flight |
Control authority
| Boundary | Sign-off |
|---|---|
| A stop is not energy isolation. No human exposure to live mechanisms is authorized by these bench observations; isolation record governs servicing. | Sam / Jordan / Ira signed June 18; Alex Meadow accepted June 25; Robin welfare review complete. |
Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.
Compare the reference example. Teaching data and signed dispositions: D1 scenario register.