THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD
5S audit — Basic bench and shared D1 folder
Scope: 5S audit — Basic bench and shared D1 folder. Read the observations and decisions below within their stated conditions.
Audit May 12 and June 30 · 0 absent, 1 partial, 2 sustained
| S | Before / evidence | Corrective action | After / evidence |
|---|---|---|---|
| Sort | 0: C1 and D1 pins mixed | Sam removed C1 kit to quarantine May 20 | 2: 10/10 kits only D1 |
| Set in order | 1: gauge had no home | Outline gauge and sample tray locations | 2: gauge present at marked home |
| Shine | 1: debris in latch fixture | Clean at shift end, log abnormal wear | 2: 5/5 daily logs signed |
| Standardize | 0: two instruction revisions at station | Alex issued D1 index and withdrew C1 | 2: 4/4 stations current |
| Sustain | 0: no audit owner | Ira weekly 5S walk; Robin checks welfare boundary | 2: June 23/30 audits completed |
Score and visual controls
| Score | Controls / response | Approval |
|---|---|---|
| 2/10 → 10/10 | Red quarantine tray; blue current folder; gauge outline. Missing gauge or stale revision stops work and alerts Sam. | Ira Bell audited; Alex Meadow signed June 30; next July 07 |
Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.