THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD
Corrective-action record — Basic latch escape
Scope: Corrective-action record — Basic latch escape. Read the observations and decisions below within their stated conditions.
CAR-B-D1-01
| Field | Completed entry |
|---|---|
| Problem / containment | 12 rebounds /100 dry cycles May 03; 10 prototypes quarantined same day |
| Occurrence cause | Hinge clearance stack; shim crossover reduced 12/100 to 0/100 |
| Escape cause | Visual-only inspection lacked functional retention requirement; 72/80 known states correctly judged |
| Correction | Rework affected units to keyed hinge and positive latch; Sam completed May 20 |
| Corrective action | Drawing stack review and control-plan CTQ trace required at release; Alex issued D1 checklist May 20 |
| Verification | Ira June 18: 0/1000 rebounds; 5 N pulls 10/10; checker agreement 80/80 |
| Field | Completed entry |
|---|---|
| Effectiveness | June 30 independent follow-up 200 dry cycles: 0 rebounds; station revision audit 4/4 D1 |
| Closure | Alex Meadow signed June 30; pilot scope only; reopen on first recurrence |
Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.
Compare the reference example. Teaching data and signed dispositions: D1 scenario register.