THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD

Mistake-proofing verification — D1 controls

DocumentBMT-POKA-YOKE-FOR-BOTS-D1
Revision / review dateD1 · 2027-06-30
Accountable ownerAlex Meadow

Scope: Mistake-proofing verification — D1 controls. Read the observations and decisions below within their stated conditions.

Error → prevention → challenge test

Product / likely mistakePrevention mechanismDeliberate error trialsResult / owner
Basic wrong hinge pinKeyed pin fits only D1 orientation; wrong pin rejected before closure10 reversed / 10 wrong-part insertions20/20 rejected; Sam June 18
Hotel reset while occupiedReset gated by door-state confirmation20 occupied reset requests20/20 remained occupied; 100/100 valid empty resets clear; Jordan June 18
Drone enable on resetNormally inhibited output; explicit bench authorization30 loss/reset injections30/30 inhibited; 0/1000 unsafe enables; Ira June 18

Audit / control

CheckOutcome
Can it be bypassed?No tool-free latch bypass observed; firmware checksum D1 verified; physical motor isolation witnessed. New bypass discovery stops pilot.
SustainSam owns start-of-shift challenge; Alex signed June 25; June 30 checks 3/3 correct.

Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.

Compare the reference example. Teaching data and signed dispositions: D1 scenario register.