THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD

House of quality — voice to engineering targets

DocumentBMT-QFD-HOUSE-OF-QUALITY-D1
Revision / review dateD1 · 2027-06-30
Accountable ownerAlex Meadow
Scored house: needs and weights at left, engineering relationships in the room, all six pair correlations in the roof, weighted priorities and measured targets at the base.00−0+−QFD HOUSE OF QUALITY · D1Roof: + supports; − trade-off;0 no assumed correlationNeed weights: 1–5Relationships: 9 / 3 / 1 / 0Latch retentionLocal indicationRelease inhibitManual accessBasic stays closed · 59003Hotel occupied visible · 51903Drone no unsafe release · 50193All manual recovery · 43339Weighted importance62625781Engineering targets / actualsInternal surrogate/bench onlySam/Jordan; Ira June 205 N /10 s10/10 retained0/1000 rebounds0/1000 missesOffline local lamp10/10 recovery0/1000 unsafe30/30 losses inhibitMotors isolated10/10 recoveries≥30 mm clearanceMin 32 mmRoof checks: retention ↔ manual access (−); indication ↔ manual checking (+); inhibit ↔ convenient recovery (−).Trade-offs jointly verified: 10/10 manual recoveries per product; acceptance never overrides no-flight/no-animal scope.
Scored house: needs and weights at left, engineering relationships in the room, all six pair correlations in the roof, weighted priorities and measured targets at the base.

Scope: House of quality — voice to engineering targets. Read the observations and decisions below within their stated conditions.

Relationship matrix · strong 9 / moderate 3 / weak 1 / none 0

Customer need / weightLatch retentionLocal indicationRelease inhibitManual access
Basic stays closed / 59003
Hotel tells me it is occupied / 51903
Drone never releases unexpectedly / 50193
All products easy to recover manually / 43339
Weighted importance62625781

Roof / targets / verification

Engineering characteristicRoof interactionTarget / measuredCompetitive baseline / decision
Latch retentionNegative correlation with opening effort5 N / 10 s, 10/10; manual access 10/10C1 12/100 rebounds → D1 0/1000
Local indicationPositive with manual status check0 omissions / 1000 events achievedC1 8/100 missed alerts → D1 0/1000
Engineering characteristicRoof interactionTarget / measuredCompetitive baseline / decision
Release inhibitPositive with controlled reset; negative with autonomous convenience30/30 link-loss injections inhibit; 0/1000 unsafe enablesC1 3/100 faults → D1 0/1000
Manual accessTrade-off with retention must be tested jointly10/10 recovery demonstrations each productSam / Jordan / Robin signed June 20; Alex accepted pilot scope June 25

Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.

Compare the reference example. Teaching data and signed dispositions: D1 scenario register.