THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD
Stratified failure rates — baseline pilot conditions
Scope: Stratified failure rates — baseline pilot conditions. Read the observations and decisions below within their stated conditions.
May 03 baseline; same totals as defect check sheet
| Product | Stratum | Failures / opportunities | Rate | Interpretation |
|---|---|---|---|---|
| Basic | High-clearance fixture | 16/50 | 32% | 12 latch + 4 other defects |
| Basic | Low-clearance fixture | 4/50 | 8% | No latch failures; other defects remain |
| Hotel | Dropout traces | 12/50 | 24% | 8 missed alerts + 4 other defects |
| Hotel | Steady traces | 4/50 | 8% | No missed local alerts |
| Drone | Reset during command | 4/50 | 8% | 3 unsafe enables + 1 fit fault |
| Drone | No reset overlap | 0/50 | 0% | Small synthetic sample, not zero-risk proof |
| Total | All strata | 40/300 | 13.33% | Do not hide condition differences in pooled rate |
Action and follow-up
| Finding | Owner / verified result |
|---|---|
| Equal denominators of 50 opportunities; different conditions and failure modes prevent pooling as a product league table. Test causal changes within each condition. | Sam/Jordan corrected hinge, retained state and inhibit; Ira June 18 confirmation 0/1000 each target function; Alex signed June 25. |
Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.
Compare the reference example. Teaching data and signed dispositions: D1 scenario register.