THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD

Quality chain — requirement to verified control

DocumentBMT-THE-QUALITY-CHAIN-SPECS-TO-CONTROL-PLAN-D1
Revision / review dateD1 · 2027-06-30
Accountable ownerAlex Meadow

Scope: Quality chain — requirement to verified control. Read the observations and decisions below within their stated conditions.

Closed-loop traceability

Need → requirementFailure / causeTest / actualControl / reaction
Basic stays closed → B-RET-01 5 N / 10 sDF01 rebound / clearance stackTR-B-D1 0/1000 cycles, 10/10 pullsCP-B01 gauge each unit; quarantine on first miss
Hotel local occupancy → H-IND-01 no omissionsDF-H08 dropout clears stateTR-H-D1 0/1000 events, 10/10 offline indicationCP-H01 firmware checksum + occupied/reset test each unit
Drone no unsafe release → D-INH-01DF-D23 reset permissiveTR-D-D1 0/1000 unsafe enables; 30/30 loss inhibitsCP-D01 witness isolation and inhibit before every bench run

Authority

ConfigurationApproval
D1 drawing / state machine → DFMEA → test → control plan → WI all linked by requirement IDsSam/Jordan prepared; Ira checked June 18; Alex signed June 25, Robin confirmed bench-only boundary.

Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.

Compare the reference example. Teaching data and signed dispositions: D1 scenario register.