| Step | Instruction | Linked control | Record / reaction |
|---|---|---|---|
| P01 | Verify correct Capture door configuration; Add positive over-center latch and keyed hinge pin | CP01 | Log unit ID, revision and actual reading against R01; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P02 | Verify correct Ventilation ribs configuration; Raise vents on opposing walls; add no-bedding instructions | CP02 | Log unit ID, revision and actual reading against R02; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P03 | Verify correct Release slider configuration; Extend external slider and add hold-open detent | CP03 | Log unit ID, revision and actual reading against R03; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P04 | Verify correct Washable shell configuration; Round internal corners; detach door cassette; hygiene instructions | CP04 | Log unit ID, revision and actual reading against R04; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P05 | Verify correct Bait pocket configuration; Integrate pocket into shell; no loose insert | CP05 | Log unit ID, revision and actual reading against R05; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P06 | Verify correct Occupancy inspection configuration; Transparent inspection window; explicit do-not-leave-unattended warning | CP06 | Log unit ID, revision and actual reading against R06; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P07 | Verify correct Entry baffle configuration; Separate entry vestibule with anti-backdrive stop | CP07 | Log unit ID, revision and actual reading against R07; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P08 | Verify correct Occupancy sensor configuration; Use independent beam and weight checks; show uncertain as occupied | CP08 | Log unit ID, revision and actual reading against R08; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P09 | Verify correct Wi-Fi alert queue configuration; Offline local indicator; queued alerts and no-cloud-needed manual checks | CP09 | Log unit ID, revision and actual reading against R09; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P10 | Verify correct BLE provisioning configuration; Authenticated pairing; expiring setup window; no shared password | CP10 | Log unit ID, revision and actual reading against R10; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P11 | Verify correct Firmware updater configuration; Signed dual-bank firmware with rollback and independent indicator | CP11 | Log unit ID, revision and actual reading against R11; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P12 | Verify correct Rechargeable pack configuration; Protected replaceable pack; keyed certified-candidate charger; thermal cutoff | CP12 | Log unit ID, revision and actual reading against R12; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P13 | Verify correct Electronics cassette configuration; Separate dry cassette with keyed seal and wash label | CP13 | Log unit ID, revision and actual reading against R13; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P14 | Verify correct Account and cloud configuration; Local-first alerts; minimal pseudonymous event data; documented deletion | CP14 | Log unit ID, revision and actual reading against R14; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P15 | Verify correct Radio module integration configuration; Freeze antenna/layout; RF lab review before launch | CP15 | Log unit ID, revision and actual reading against R15; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P16 | Verify correct Crowded chamber configuration; Independent compartments and ventilation; inhibit further entry if full | CP16 | Log unit ID, revision and actual reading against R16; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P17 | Verify correct Wall-side deployment carriage configuration; Guard pinch points and torque-limit drive; positive travel stops | CP17 | Log unit ID, revision and actual reading against R17; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P18 | Verify correct Payload coupler configuration; Captive redundant latch and diverse seated sensors | CP18 | Log unit ID, revision and actual reading against R18; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P19 | Verify correct Propeller guards configuration; Full guards; hardware arm inhibit; emergency motor stop | CP19 | Log unit ID, revision and actual reading against R19; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P20 | Verify correct Navigation estimator configuration; Independent supervisor; no public flight in sample phase | CP20 | Log unit ID, revision and actual reading against R20; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P21 | Verify correct Mission battery configuration; Energy budget check before takeoff; abort to safe landing | CP21 | Log unit ID, revision and actual reading against R21; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P22 | Verify correct Command link configuration; Independent flight controller and local abort plan | CP22 | Log unit ID, revision and actual reading against R22; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P23 | Verify correct Field release door configuration; Hardware ground/motor interlock plus software sequence checks | CP23 | Log unit ID, revision and actual reading against R23; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P24 | Verify correct Release destination configuration; Approved destination registry; human review before mission enable | CP24 | Log unit ID, revision and actual reading against R24; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P25 | Verify correct Aircraft operation scope configuration; Research-only simulation; human-supervised feasibility path with trained operator | CP25 | Log unit ID, revision and actual reading against R25; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P26 | Verify correct Remote ID equipment configuration; Qualified aircraft/Remote ID integration review; do not infer exemption | CP26 | Log unit ID, revision and actual reading against R26; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P27 | Verify correct Charging dock contacts configuration; Enclosed contacts; current limiting and sensor disagreement shutdown | CP27 | Log unit ID, revision and actual reading against R27; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P28 | Verify correct Weather monitor configuration; Local weather interlock; fail closed on missing/stale reading | CP28 | Log unit ID, revision and actual reading against R28; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P29 | Verify correct Autonomy cybersecurity configuration; Secure boot; signed missions; least-privilege command channels | CP29 | Log unit ID, revision and actual reading against R29; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P30 | Verify correct Return docking configuration; Independent dock fiducial check; keep-out zone and supervised abort | CP30 | Log unit ID, revision and actual reading against R30; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
Sample — fictitious company. All numbers and people are invented scenario assumptions. This is draft concept paperwork; no physical testing, customer evidence, certification, filing or sign-off has occurred.