The Better Mouse Trap Co. / sample paperwork

Risk Table

Sample — fictitious company

Sample — fictitious company. All numbers and people are invented scenario assumptions. This is draft concept paperwork; no physical testing, customer evidence, certification, filing or sign-off has occurred.

Mouse HotelRevision C12026-10-24sample-draft32 entries
Risk Table
idFailure mode / actionseffectSODRPNstatus
DF01Capture door: Door rebounds after entryMouse escapes; repeated handling increases bite exposure756210open — first-pass proposed
DF01-MAdd positive over-center latch and keyed hinge pinMouse escapes; repeated handling increases bite exposure73484open — projected mitigation, not accepted
DF02Ventilation ribs: Air paths blocked by nesting materialConfined mouse distress or death947252open — first-pass proposed
DF02-MRaise vents on opposing walls; add no-bedding instructionsConfined mouse distress or death92590open — projected mitigation, not accepted
DF03Release slider: Finger enters closing-door pathPinch or bite during release846192open — first-pass proposed
DF03-MExtend external slider and add hold-open detentPinch or bite during release82464open — projected mitigation, not accepted
DF04Washable shell: Soiled corners retain contaminationUser exposure to rodent waste856240open — first-pass proposed
DF04-MRound internal corners; detach door cassette; hygiene instructionsUser exposure to rodent waste83496open — projected mitigation, not accepted
DF05Bait pocket: Bait holder detachesSmall-part ingestion by child or pet936162open — first-pass proposed
DF05-MIntegrate pocket into shell; no loose insertSmall-part ingestion by child or pet91436open — projected mitigation, not accepted
DF06Occupancy inspection: User leaves occupied trap uncheckedAnimal dehydration and distress968432open — first-pass proposed
DF06-MTransparent inspection window; explicit do-not-leave-unattended warningAnimal dehydration and distress946216open — projected mitigation, not accepted
DF07Entry baffle: Second mouse opens occupied chamberEscape or animal injury857280open — first-pass proposed
DF07-MSeparate entry vestibule with anti-backdrive stopEscape or animal injury835120open — projected mitigation, not accepted
DF08Occupancy sensor: False empty statusUser neglects occupied enclosure958360open — first-pass proposed
DF08-MUse independent beam and weight checks; show uncertain as occupiedUser neglects occupied enclosure936162open — projected mitigation, not accepted
DF09Wi-Fi alert queue: Alert never arrivesDelayed inspection harms captured animal968432open — first-pass proposed
DF09-MOffline local indicator; queued alerts and no-cloud-needed manual checksDelayed inspection harms captured animal946216open — projected mitigation, not accepted
DF10BLE provisioning: Nearby stranger pairs to trapUnauthorized control and household occupancy disclosure858320open — first-pass proposed
DF10-MAuthenticated pairing; expiring setup window; no shared passwordUnauthorized control and household occupancy disclosure836144open — projected mitigation, not accepted
DF11Firmware updater: Corrupt update disables occupancy indicationOccupied trap appears inactive948288open — first-pass proposed
DF11-MSigned dual-bank firmware with rollback and independent indicatorOccupied trap appears inactive926108open — projected mitigation, not accepted
DF12Rechargeable pack: Battery overheats during chargingBurn or fire1048320open — first-pass proposed
DF12-MProtected replaceable pack; keyed certified-candidate charger; thermal cutoffBurn or fire1026120open — projected mitigation, not accepted
DF13Electronics cassette: Wash water reaches PCBShock from faulty adapter or overheating957315open — first-pass proposed
DF13-MSeparate dry cassette with keyed seal and wash labelShock from faulty adapter or overheating935135open — projected mitigation, not accepted
DF14Account and cloud: Household presence patterns retainedPrivacy loss after breach758280open — first-pass proposed
DF14-MLocal-first alerts; minimal pseudonymous event data; documented deletionPrivacy loss after breach736126open — projected mitigation, not accepted
DF15Radio module integration: Host changes invalidate RF assumptionsBlocked market access or interference958360open — first-pass proposed
DF15-MFreeze antenna/layout; RF lab review before launchBlocked market access or interference936162open — projected mitigation, not accepted
DF16Crowded chamber: Animals compete or overheatInjury to trapped animals958360open — first-pass proposed