| Step | Instruction | Linked control | Record / reaction |
|---|---|---|---|
| P01 | Verify correct Capture door configuration; Add positive over-center latch and keyed hinge pin | CP01 | Log unit ID, revision and actual reading against R01; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P02 | Verify correct Ventilation ribs configuration; Raise vents on opposing walls; add no-bedding instructions | CP02 | Log unit ID, revision and actual reading against R02; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P03 | Verify correct Release slider configuration; Extend external slider and add hold-open detent | CP03 | Log unit ID, revision and actual reading against R03; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P04 | Verify correct Washable shell configuration; Round internal corners; detach door cassette; hygiene instructions | CP04 | Log unit ID, revision and actual reading against R04; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P05 | Verify correct Bait pocket configuration; Integrate pocket into shell; no loose insert | CP05 | Log unit ID, revision and actual reading against R05; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P06 | Verify correct Occupancy inspection configuration; Transparent inspection window; explicit do-not-leave-unattended warning | CP06 | Log unit ID, revision and actual reading against R06; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P07 | Verify correct Entry baffle configuration; Separate entry vestibule with anti-backdrive stop | CP07 | Log unit ID, revision and actual reading against R07; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P08 | Verify correct Occupancy sensor configuration; Use independent beam and weight checks; show uncertain as occupied | CP08 | Log unit ID, revision and actual reading against R08; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P09 | Verify correct Wi-Fi alert queue configuration; Offline local indicator; queued alerts and no-cloud-needed manual checks | CP09 | Log unit ID, revision and actual reading against R09; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P10 | Verify correct BLE provisioning configuration; Authenticated pairing; expiring setup window; no shared password | CP10 | Log unit ID, revision and actual reading against R10; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P11 | Verify correct Firmware updater configuration; Signed dual-bank firmware with rollback and independent indicator | CP11 | Log unit ID, revision and actual reading against R11; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P12 | Verify correct Rechargeable pack configuration; Protected replaceable pack; keyed certified-candidate charger; thermal cutoff | CP12 | Log unit ID, revision and actual reading against R12; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P13 | Verify correct Electronics cassette configuration; Separate dry cassette with keyed seal and wash label | CP13 | Log unit ID, revision and actual reading against R13; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P14 | Verify correct Account and cloud configuration; Local-first alerts; minimal pseudonymous event data; documented deletion | CP14 | Log unit ID, revision and actual reading against R14; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P15 | Verify correct Radio module integration configuration; Freeze antenna/layout; RF lab review before launch | CP15 | Log unit ID, revision and actual reading against R15; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
| P16 | Verify correct Crowded chamber configuration; Independent compartments and ventilation; inhibit further entry if full | CP16 | Log unit ID, revision and actual reading against R16; hold suspect units, notify Jordan Vale, repeat after correction before authorized restart |
Sample — fictitious company. All numbers and people are invented scenario assumptions. This is draft concept paperwork; no physical testing, customer evidence, certification, filing or sign-off has occurred.