THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD

Stop and fail-safe verification sheet

DocumentBMT-E-STOPS-AND-FAIL-SAFE-D1
Revision / review dateD1 · 2027-06-30
Accountable ownerAlex Meadow

Scope: Stop and fail-safe verification sheet. Read the observations and decisions below within their stated conditions.

Surrogate rigs · June 18

Product / energyStop demandSafe state / resetMeasured trialDisposition
Basic / spring and hand forceStop cycle and isolate rig supplyDoor remains mechanically retained; deliberate manual reset10/10 rig stops; retention 5 N 10/10Sam: pilot accepted
Hotel / low-voltage supplySupply removal or operator stopNo powered movement; manual access retained; occupied indication checked locally10/10 power-loss manual recoveries; restart 10/10 requires resetJordan: supervised bench accepted
Drone / isolated actuator, motors disconnectedLink loss or bench stopRelease inhibit de-energized; no auto restart30/30 link losses inhibit; 10/10 stop/reset sequences safeIra: bench accepted; no flight

Control authority

BoundarySign-off
A stop is not energy isolation. No human exposure to live mechanisms is authorized by these bench observations; isolation record governs servicing.Sam / Jordan / Ira signed June 18; Alex Meadow accepted June 25; Robin welfare review complete.

Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.

Compare the reference example. Teaching data and signed dispositions: D1 scenario register.