THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD

Corrective-action record — Basic latch escape

DocumentBMT-FIX-THE-CAUSE-NOT-THE-ANSWER-D1
Revision / review dateD1 · 2027-06-30
Accountable ownerAlex Meadow

Scope: Corrective-action record — Basic latch escape. Read the observations and decisions below within their stated conditions.

CAR-B-D1-01

FieldCompleted entry
Problem / containment12 rebounds /100 dry cycles May 03; 10 prototypes quarantined same day
Occurrence causeHinge clearance stack; shim crossover reduced 12/100 to 0/100
Escape causeVisual-only inspection lacked functional retention requirement; 72/80 known states correctly judged
CorrectionRework affected units to keyed hinge and positive latch; Sam completed May 20
Corrective actionDrawing stack review and control-plan CTQ trace required at release; Alex issued D1 checklist May 20
VerificationIra June 18: 0/1000 rebounds; 5 N pulls 10/10; checker agreement 80/80
FieldCompleted entry
EffectivenessJune 30 independent follow-up 200 dry cycles: 0 rebounds; station revision audit 4/4 D1
ClosureAlex Meadow signed June 30; pilot scope only; reopen on first recurrence

Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.

Compare the reference example. Teaching data and signed dispositions: D1 scenario register.