THE BETTER MOUSE TRAP CO. · COMPLETED METHOD RECORD
Work instruction — D1 pilot setup and stop
Product parts / controlled detailed instructions
| Product | Parts and physical boundary | Executed record |
|---|---|---|
| Basic | Mechanical shell, capture door, acetal trigger, molded over-center, keyed pin, external slider, integral pocket, clear pane, label and instruction sheet. No separate spring or electronics. | 14 station route; identify keyed hinge orientation, 30 mm keep-out, two raised vents and 5 N retention; 10/10 traveler checks. |
| Mouse Hotel | Three separated chambers and baffles, optical sensors, local occupied lamp, signed controller and detachable dry cassette. Cabled simulation; electronics removed before wash. | 21 station route; cassette-unseat forces enable low, offline lamp visible and local flag retained; 10/10 removal checks. |
| Drone Trap | Stationary capsule, redundant retention paths, isolated controller, rail, four guards, dry cassette and manual. Motor disconnect locked; no pack/propellers. | 34 station route; verify zero motor bus, ground/motor interlocks and HIL case/image trace; 3/3 isolated fixture setups. |
basic full station instruction, hotel full station instruction, drone full station instruction
Scope: Work instruction — D1 pilot setup and stop. Read the observations and decisions below within their stated conditions.
WI-D1 · effective June 20; operator Sam / Jordan; verifier Ira
| Step | Basic | Mouse Hotel | Drone Trap | Record / reaction |
|---|---|---|---|---|
| 1 Identify | D1 hinge kit, gap gauge | D1 firmware checksum and trace manifest | D1 inhibit drawing; motor pack removed | Serial and revision in setup log; mismatch stops work |
| 2 Prepare | Guard rig; hands out of moving path | Unloaded chamber, local indicator visible | Actuator guarded; exclusion zone; isolation witness | Ira signs setup; no live payload |
| 3 Challenge | Wrong pin must not seat; 5 N retention pull | Occupied reset refused; empty reset clears | Link-loss must inhibit | Failure quarantines setup; Sam/Jordan investigate |
| 4 Run | 100 dry cycles per ten units | 1000 simulated events | 1000 isolated commands + 30 loss injections | Log actual separately; preserve failures |
| 5 Close | 0/1000 rebounds; 10/10 pulls | 0/1000 misses; 100/100 valid resets | 0/1000 unsafe enables; 30/30 inhibited | Ira signs June 18; Alex accepts June 25; no unilateral restart |
Training
| Evidence | Approval |
|---|---|
| 2/2 operators demonstrated correct setup; June 30 review 3/3 benches correct | Alex signed June 20; Robin confirmed no animal or flight work. |
Record reviewed and signed: Alex Meadow, 2027-06-30. Technical review: Sam Reed / Jordan Vale; independent check: Ira Bell. Disposition: use for the stated internal scope only.
Compare the reference example. Teaching data and signed dispositions: D1 scenario register.